Simple Controls - |
A user friendly digital display unit mounted on the alarm panel facia can return and display in sequence up to one hundred active or previous faults, giving the date and the time information, also whether the fault was acknowledged by farm personnel. |
| ■ |
Dial Out Feature - Optional Extra |
Our auto dialer enables four telephone numbers to be easily installed and messages to be easily recorded. The dialer features an LCD display, which confirms the numbers being punched in. |
| ■ |
Time Out Feature - Optional Extra |
This enables a designated channels to be 'put on hold', on a timer, whilst farm work is carried out, which may affect the panel. If the panel is not reset after the work is complete, it does it itself at the end of the times period. This eliminates the need to turn off the panel. |
| ■ |
Mute Feature - |
This enables alarm dial out and audible alarm to be switched off, on a built in timer, whilst the alarm situation is dealt with. If the alarm does not detect that the problem is solved within a set time, it will reactivate at the end of the time period. |
| ■ |
Cancel Feature - |
An extension to the alarm mute facility. The alarm cancel can be used to prevent re-activation of the audible and dial out alarms, until the fault is fully repaired. |
| ■ |
Time Delay Feature - |
Factory set delay (usually 10 seconds), prevents bouncing on and off of alarm system by ensuring the alarm condition is constant before activating alarm system.
|